Past the Envelope · Issue 5
Firefighter Heat Monitoring Without a Budget: The One Number a Rehab Officer Can Use
Every fire service is resource constrained. The question officers ask after the physiology is whether any of it can be done without money, and the answer is yes: heart rate is the best single marker of heat strain a rehab officer has, and it needs a watch and two fingers.
A fire service can monitor firefighters for heat strain with no equipment budget by using heart rate at the end of the rest period. As core temperature rises, blood is diverted to the skin, blood pressure falls, and the heart compensates by pumping more often, so an elevated heart rate at rest is a direct marker of unresolved heat load. NFPA 1584 sets the threshold at 120 beats per minute: a firefighter above 120 after rest is not ready for re-entry. A watch and a pulse at the wrist are enough; heart rate monitors make it easier to see a whole crew at once but are not required.
From the keynote Past the Envelope: Heat, Tolerance and What Command Owes the Crew, ARFFWG International Symposium, Christchurch, October 2026. Starts at the section this issue is built on; the full talk runs 55 minutes with chapters.
Why is heart rate the right number?
Think of the circulation as a pump with two settings, pressure and volume, the way an older truck had switches for each. As a firefighter heats up, the body sends blood to the skin to shed heat. The vessels open, the pressure in the system drops, and the pump makes up the difference with volume, which is heart rate. In the 42-firefighter blood study behind the keynote, crews doing a crawling search task in the chamber were at 91 per cent of their age-predicted maximum heart rate, and that was before anyone was running or hauling hose.
The useful property is that heart rate does not decouple the way sensation does. When a firefighter comes out of an evolution, takes the jacket off and feels fine, the heart is still carrying the load their core is carrying. Ask how they feel and you get the skin. Count the pulse and you get the core, approximately but reliably enough to make a decision.
What is the number, and how do you take it?
NFPA 1584 puts the re-entry threshold at 120 beats per minute, and it holds up against measured core temperature. A firefighter above 120 at the end of the rest period is not ready to go back in, whatever they tell you. Below 120, with the rest of the rehab done, they are a reasonable bet.
Taking it costs nothing. Two fingers on the radial pulse at the wrist, count for fifteen seconds, multiply by four. Do it in the last minute of the rest period, not the first, because the number is still falling early on. Write it next to the name on the rehab sheet. If the service can afford chest-strap or wrist monitors, the rehab officer can see a whole crew on one screen, and the monitors are the first thing I would buy before any other piece of heat equipment, but the decision does not wait for them.
What else does an officer get for free?
The behaviour of the crew. Comms are the first thing to go: a crew that was chatty on the radio goes quiet, and when they do talk the message is garbled or poorly thought through. On the fireground in the Canberra job that opens the keynote, that was the first sign my crew were in trouble, well before anyone looked unwell. In rehab, the firefighter who is usually funny and suddenly wants to punch someone, or who is not making sense, is giving you a reading as clear as a thermometer. You know your people. If that is normal for them, fine. If it is not, they are cooking.
And a roll call. Who has just come back from leave, who has been sick for a fortnight, who did the hot course yesterday. The envelope is different for each of them, and knowing it at the start of the day is a control that costs a question.
What should the rehab sheet look like?
Name, time out, pulse at the end of rest, what cooling they had, and a column for the officer's call on re-entry. If the service has a core temperature capability, add it; if not, the sheet still works. Over a season that sheet becomes the exposure record from Issue 2, and over a career it becomes the evidence that the service was looking.
This is a shorter issue, written for the week between Christmas and New Year, which is also the first hot week for most of the southern services reading it. Next issue, in the new year: why averages do not work on a crew of twelve.
Frequently asked questions
How can a fire service monitor heat stress without core temperature monitors?
With heart rate at the end of the rest period. Rising core temperature pushes blood to the skin, lowers blood pressure, and the heart compensates by beating faster, so a firefighter whose heart rate is still elevated after rest has not recovered. NFPA 1584 sets 120 beats per minute as the re-entry threshold, and a pulse count at the wrist is sufficient to apply it.
What heart rate means a firefighter should not re-enter?
Above 120 beats per minute at the end of the rest period, under NFPA 1584. The count should be taken in the last minute of rest rather than the first, because heart rate is still falling early in the period. Heart rate monitors make it easier to watch a whole crew but are not needed to apply the threshold.
What are the early behavioural signs of heat stress in a firefighter?
Changes in communication and temperament. Crews go quiet on the radio and their messages become garbled or poorly reasoned; in rehab, irritability, aggression about nothing, confusion or not making sense are early signs that the brain is affected. An officer who knows the crew's normal behaviour can read these signs before any physical collapse.
What is on your rehab sheet today?
The heat-season readiness audit looks at the rehab record your service keeps and what decisions it can support. It is a short conversation to begin.
Book a strategy call